Showing results: 211 - 225 of 340 items found.
-
GDYT Series -
HV Hipot Electric Co.,Ltd.
GDYT series include partial discharge power frequency testing transformer(YDTW),partial discharge detector(GDJF2008),Isolation filter frequency doubling power device(GDSF-81G) and power frequency withstand voltage control table(GDYD table).It widely used in electrical manufacturing,power operation departments, research institutes and universities.
-
CP RC -
OMICRON electronics
For HV testing OMICRON’s CPC 100 + CP RC are directly connected to the voltage transformer of the GIS, forming a resonance circuit. This reinforced “Power VT” is an integrated part of the GIS. So the need for draining and refilling any SF6 gas is eliminated. Acting as both the measuring and controlling device, the CPC 100 injects the required energy.
-
2000A -
SCR ELEKTRONIKS
SCR ELEKTRONIKS have developed “TEMPERATURE RISE TEST BENCH FOR MEDIUM VOLTAGE SWITCH BOARDS” to measure rise in temperature at various points as mentioned in standard at junctions. The set-up consists of a True RMS Constant Current Source (to maintain the Current within + / - 1 % of set value with Digital Indication), PC based control system, Temperature data logging on PC, Servo-Controller and other indications. Digital voltmeter Primary Voltage) indicates the position of auto transformer (variac).
-
Pulse Electronics
Current sense magnetics are used as a low loss method for sensing AC current in a circuit and also provide electrical and safety isolation between the source of the current and the measurement circuit. The key parameters for a current sense transformer are the rms current rating (to ensure it does not overheat in the application) and the safety and voltage isolation (to ensure it conforms to the end-application requirements).
-
MIB -
GE Digital Energy
The MIB, a member of the M II family of economical and highly functional digital protection relays, is a microprocessor based relay that provides three phase high impedance differential protection for Substation Bus-bars of any voltage level. Use the MIB also to protect electrical machines like transformers, generators or motors against restricted earth faults.
-
Supreme Instrument Laboratories
Loading Rheostat is a device specially designed to meet the requirements of Engineering Laboratories, Electrical Test Rooms and Industries. It is used for loading transformers, power generators, supply mains etc. neatly and efficiently. It can also be used advantageously for regulating current and adjusting voltage besides its application for calibrating meters and thus eliminating the need for graded rheostats.
-
EC Series -
Semiconductor Circuits, Inc.
The EC Series of line operated power supplies features near constant efficiency over theentire rated input voltage range. These electrically identical families employ a highly efficient, closed loop ripple regulation circuit, which contains a low pass filter. Each stage, transformer, filter and regulator is engineered for maximum efficiency.
-
ES Series -
Semiconductor Circuits, Inc.
The ES Series of line operated power supplies features near constant efficiency over theentire rated input voltage range. These electrically identical families employ a highly efficient, closed loop ripple regulation circuit, which contains a low pass filter. Each stage, transformer, filter and regulator is engineered for maximum efficiency.
-
EA Series -
Semiconductor Circuits, Inc.
The EA Series of line operated power supplies features near constant efficiency over theentire rated input voltage range. These electrically identical families employ a highly efficient, closed loop ripple regulation circuit, which contains a low pass filter. Each stage, transformer, filter and regulator is engineered for maximum efficiency.
-
BATLV1600 -
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations. These equipments are supplied completely assembled and ready for use: it is only necessary to connect it to the mains with cablesof adequate cross section, and to supply the operation signal from suitable current transformer. FML capacitors and swichgear inside metal cabinet. Floor mounting.
-
GDZG-300 Series -
HV Hipot Electric Co.,Ltd.
GDZG-300 series of DC high voltage tester is used for testing DC high voltage for zinc oxide arrester, magnetic blowing arrester, power cables, generators, transformers, switches and other equipments. It is suitable for electric power branch, power department of factories, scientific research units, railway, chemical industry, and power plants.
-
TTRM 101 -
Scope T&M Pvt, Ltd.
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 101 measures only turns ratio where as TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
SL1203A -
Keysight Technologies
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
SL1214A -
Keysight Technologies
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
SL1201A -
Keysight Technologies
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.